? Direct solenoid shutoff valve
? Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H
? No leak
? Responsive switching under high pressure
? Replacing the coil does not require opening the sealed chamber
? Solenoid coil can rotate 90°
? With manual emergency control optional
Specifications | NG6 | NG10 | ||
Installation position | Optional | |||
Environment temperature | ℃ | -30 to +50 (NBR seals) | ||
-20 to +50 (FKM seals) | ||||
Weight | Two three-way solenoidic directional valve | Kg | 1.5 | 2.6 |
Two four-way solenoidic directional valve | Kg | 2.3 | 3.9 | |
Max. operating pressure | bar | 350 | 350 | |
Max. flow-rate | L/min | 25 | 40 | |
Fluid | Mineral oil suitable for NBR and FKM seal | |||
Phosphate ester for FKM seal | ||||
Fluid temperature range | ℃ | -30 to +80 (NBR seals) | ||
-20 to +80 (FKM seals) | ||||
Viscosity range | mm2/s | 2.8 to 500 | ||
Degree of contamination | Maximum permissible degree of fluid contamination: Class 9. NAS 1638 | Maximum permissible degree of fluid contamination: Class 9. NAS 1638 or 20/18/15, ISO4406 |
ADD: Address: No. 81, Zhuhang Road, Minhang District, Shanghai(Shanghai Lixin Hydraulics Co., Ltd.)
TEL: 021-31616718 Tel: 021-31616718, ext. 8000 ( reception )
? 2023 Shanghai Lixin Hydraulics Co., Ltd. copyright hu13042344