? Electrohydraulic directioanl valve directioanls the oil path by controlling the main spool
? WEH electrohydraulic control
? Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection
? Wet DC or AC solenoid (optional)
? With manual emergency control
? Electropneumatic connection as single or center connection
? Spring or hydraulic alignment or bias
NG10
Specifications | H-WEH10 type | WEH10 type | ||||||||
Max. operating pressure:P、A、B | 350 | 280 | ||||||||
Port T | With external pilot oil drain bar | 315 | ||||||||
With internal pilot oil drain bar | DC 210 AC 160 | |||||||||
Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||
Min. control pressure | With external pilot oil supply ( not apply to C、Z、 F、G、H、P、T、V) bar | 3-position valve 10 | ||||||||
Spring-return 2-position valve 10 | ||||||||||
Hydraulic-return 2-position valve 7 | ||||||||||
With internal pilot oil supply ( apply to C、Z、F、 G、H、P、T、V) bar | 6.5 | |||||||||
Max. control pressure bar | 250 | |||||||||
Fluid | Mineral oil,Phosphate ester | |||||||||
Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||
-20 to +80 ( FKM seals ) | ||||||||||
Viscosity range mm2/s | 2.8 to 500 | |||||||||
Switching pilot oil volume cm3 | 3-position valve 2.04 | |||||||||
2-position valve 4.08 | ||||||||||
Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC ) | ||||||||||
Control pressure bar | 70 | 140 | 210 | 250 | ||||||
AC | DC | AC | DC | AC | DC | AC | DC | |||
3-position valve ms | 30 | 65 | 25 | 60 | 20 | 55 | 15 | 50 | ||
2-position valve ms | 35 | 80 | 30 | 75 | 25 | 70 | 20 | 65 | ||
Switching times (= Valve switching time from the switched position to the neutral position) | ||||||||||
3-position valve ms | 30 | |||||||||
2-position valve ms | 35 | 40 | 30 | 35 | 25 | 30 | 20 | 25 | ||
Installation position | HC、HD、HK、HZ、HY Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||
Flow of shortest switching time L/min | about 35 | |||||||||
Weight | Single solenoid valve kg | 6.7 | ||||||||
Double solenoid valve kg | 7.1 | |||||||||
Switching time regulator kg | 1.0 | |||||||||
Reducing valve kg | 0.5 |
NG16
Specifications | H-...WEH16... type | ...WEH16... type | ||||||||||||
Max. operating pressure:P、A、B | 350 | |||||||||||||
Port T | With external pilot oil drain bar | 250 | ||||||||||||
With internal pilot oil drain bar | DC 210 AC 160 | |||||||||||||
Hydraulic-centering 3-position valve With internal pilot oil drain is impossible | ||||||||||||||
Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||||||
Min. control pressure | With external pilot oil supply ( not apply to C、Z、 | 3-position valve 14 | ||||||||||||
Spring-return 2-position valve 14 | ||||||||||||||
Hydraulic-return 2-position valve 14 | ||||||||||||||
With internal pilot oil supply ( apply to C、Z、F、 G、 H、P、T、V) bar | When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V | |||||||||||||
Max. control pressure bar | 250 | |||||||||||||
Fluid | Mineral oil,Phosphate ester | |||||||||||||
Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||||||
-20 to +80 ( FKM seals ) | ||||||||||||||
Viscosity range mm2/s | 2.8 to 500 | |||||||||||||
Switching pilot oil volume | ||||||||||||||
- Spring-centering 3-position valve cm3 | 5.72 | |||||||||||||
- 2-position valve cm3 | 11.45 | |||||||||||||
Hydraulic-centering 3-position valve | ||||||||||||||
- From"0"position to working position"a" cm3 | 2.83 | |||||||||||||
- From working position"a" to "0"position cm3 | 2.9 | |||||||||||||
- From"a"position to working position"b" cm3 | 5.72 | |||||||||||||
- From working position"b" to "0"position cm3 | 2.83 | |||||||||||||
* * Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC) | ||||||||||||||
Control pressure bar | 50 | 150 | 250 | |||||||||||
AC | DC | AC | DC | AC | DC | AC | DC | AC | DC | AC | DC | |||
- Spring-centering 3-position valve ms | 35 | 65 | 30 | 60 | 30 | 58 | ||||||||
- 2-position valve ms | 45 | 65 | 35 | 55 | 30 | 50 | ||||||||
- Hydraulic-centering 3-position valve ms | / | b | a | b | a | b | a | b | a | b | a | b | ||
30 | 65 | 25 | 55 | 63 | 20 | 25 | 55 | 60 | ||||||
**Switching times (= Valve switching time from the neutral position to the switched position) | ||||||||||||||
- Spring-centering 3-position valve ms | 30 | |||||||||||||
- 2-position valve ms | 45 | 45 | 35 | 35 | 30 | 30 | ||||||||
- Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | ||
20 | 20 | 20 | 20 | 20 | 20 | |||||||||
Installation position | C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||||||
Flow of shortest switching time L/min | about 35 | |||||||||||||
Weight kg | about 9.5 |
NG25
Specifications | H-...WEH25... type | ...WEH25... type | ||||||||||||||||
Max. operating pressure:P、A、B | 350 | 280 | ||||||||||||||||
Port T | With external pilot oil drain bar | 250 | ||||||||||||||||
With internal pilot oil drain bar | DC 210 AC 160 | |||||||||||||||||
Hydraulic-centering 3-position valve With internal pilot oil drain is impossible | ||||||||||||||||||
Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||||||||||
Min. control pressure | With external pilot oil supply ( not apply to C、Z、F、 | Spring-centering 3-position valve 13 | ||||||||||||||||
Hydraulic-centering 3-position valve 18 | ||||||||||||||||||
Spring-return 2-position valve 13 | ||||||||||||||||||
Hydraulic-return 2-position valve 8 | ||||||||||||||||||
With internal pilot oil supply ( apply to C、Z、F、 G、H、P、T、V) bar | When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V | |||||||||||||||||
Max. control pressure bar | 250 | |||||||||||||||||
Fluid | Mineral oil,Phosphate ester | |||||||||||||||||
Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||||||||||
-20 to +80 ( FKM seals ) | ||||||||||||||||||
Switching pilot oil volume | ||||||||||||||||||
- Spring-centering 3-position valve cm3 | 14.2 | |||||||||||||||||
- 2-position valve cm3 | 28.4 | |||||||||||||||||
Hydraulic-centering 3-position valve | ||||||||||||||||||
- From"0"position to working position"a" cm3 | 7.15 | |||||||||||||||||
- From working position"a" to "0"position cm3 | 7.0 | |||||||||||||||||
-From "0"position to working position"b" cm3 | 14.15 | |||||||||||||||||
-From working position"b" to "0"position cm3 | 5.73 | |||||||||||||||||
* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC) | ||||||||||||||||||
Control pressure bar | 50 | 140 | 210 | 250 | ||||||||||||||
AC | DC | AC | DC | AC | DC | AC | DC | |||||||||||
- Spring-centering 3-position valve ms | 50 | 85 | 40 | 75 | 35 | 70 | 30 | 65 | ||||||||||
- 2-position valve ms | 120 | 160 | 100 | 130 | 85 | 120 | 70 | 105 | ||||||||||
- Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | a | b | a | b | ||
30 | 35 | 55 | 65 | 30 | 35 | 55 | 65 | 25 | 30 | 50 | 60 | 25 | 30 | 50 | 60 | |||
*Switching times (= Valve switching time from the neutral position to the switched position) | ||||||||||||||||||
- Spring-centering 3-position valve ms | 40 | |||||||||||||||||
- 2-position valve ms | 120 | 125 | 95 | 100 | 85 | 90 | 75 | 80 | ||||||||||
- Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | a | b | a | b | ||
20 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | 30 | 35 | |||
Installation position | C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||||||||||
Flow of shortest switching time L/min | about 35 | |||||||||||||||||
Weight kg | about 18 |
NG32
Specifications | H-...WEH32... type | ...WEH32... type | ||||||||||||
Max. operating pressure:P、A、B | 350 | 280 | ||||||||||||
Port T | With external pilot oil drain bar | 250 | ||||||||||||
With internal pilot oil drain bar | DC 210 AC 160 | |||||||||||||
Hydraulic-centering 3-position valve With internal pilot oil drain is impossible | ||||||||||||||
Port Y | With external pilot oil drain bar | DC 210 AC 160 | ||||||||||||
Min. control pressure | With external pilot oil supply With internal pilot oil supply | 3-position valve 8.5 | ||||||||||||
Spring-return 2-position valve 10 | ||||||||||||||
Hydraulic-return 2-position valve 15 | ||||||||||||||
With internal pilot oil supply ( apply to C、Z、F、 G、H、P、T、V) bar | When applying prepressing or the flow is large correspondingly ,enginery of spool valve is 4.5 as C,Z,F,G,H,P,T and V | |||||||||||||
Max. control pressure bar | 250 | |||||||||||||
Fluid | Mineral oil,Phosphate ester | |||||||||||||
Fluid temperature range ℃ | -30 to +80 ( NBR seals | |||||||||||||
-20 to +80 ( FKM seals ) | ||||||||||||||
Viscosity range mm2/s | 2.8 to 500 | |||||||||||||
Switching pilot oil volume | ||||||||||||||
- Spring-centering 3-position valve cm3 | 29.4 | |||||||||||||
- 2-position valve cm3 | 58.8 | |||||||||||||
Hydraulic-centering 3-position valve | ||||||||||||||
- From"0"position to working position"a" cm3 | 14.4 | |||||||||||||
- From working position"a" to "0"position cm3 | 15.1 | |||||||||||||
- From "0"position to working position"b" cm3 | 29.4 | |||||||||||||
- From working position"b" to "0"position cm3 | 14.4 | |||||||||||||
* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC) | ||||||||||||||
Control pressure bar | 50 | 150 | 250 | |||||||||||
AC | DC | AC | DC | AC | DC | |||||||||
- Spring-centering 3-position valve ms | 65 | 80 | 50 | 90 | 35 | 105 | ||||||||
- 2-position valve ms | 100 | 130 | 75 | 100 | 60 | 115 | ||||||||
- Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | ||
55 | 60 | 100 | 105 | 40 | 45 | 85 | 95 | 35 | 40 | 85 | 95 | |||
*Switching times (= Valve switching time from the neutral position to the switched position) | ||||||||||||||
- Spring-centering 3-position valve ms | ( DC :50,AC :60) | |||||||||||||
- 2-position valve ms | 115 | 90 | 35 | 70 | 65 | 65 | ||||||||
- Hydraulic-centering 3-position valve ms | a | b | a | b | a | b | a | b | a | b | a | b | ||
30 | 50 | 30 | 40 | 60 | 75 | 30 | 30 | 105 | 140 | 50 | 50 | |||
Installation position | C、D、K、Z、YType hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily | |||||||||||||
Flow of shortest switching time L/min | about 50 | |||||||||||||
Weight kg | about 36 |
ADD: Address: No. 81, Zhuhang Road, Minhang District, Shanghai(Shanghai Lixin Hydraulics Co., Ltd.)
TEL: 021-31616718 Tel: 021-31616718, ext. 8000 ( reception )
? 2023 Shanghai Lixin Hydraulics Co., Ltd. copyright hu13042344