? Direct-acting, used for controlling flow rate and flowing direction of fluid
? Valve spool spring centering alignment
? Electromagnet operated spool action
? Optional built-in amplifier
? Suitable for overhead working trucks, metallurgy and other industries
Hydraulic | ||||||||
Installation position | optional, preferably horizontal | |||||||
Size | 6 | 10 | ||||||
Weight | 4WRA...L2X | Kg | 2 | 6.6 | ||||
4WRAE...L2X | 2.2 | 6.8 | ||||||
Rated flow qnom,when Δp = 10 bar | L/min | 7、15、26 | 30、60 | |||||
Hysteresis | % | ≤5 | ||||||
Repeatability | % | ≤1 | ||||||
Response sensitivity | % | ≤0.5 | ||||||
Max. operating pressure | Port s A B P | bar | 315 | |||||
Port T | bar | 210 | ||||||
Fluid | Mineral oil suitable for NBR and FKM seal | |||||||
Phosphate ester for FKM seal | ||||||||
Fluid temperature range | 4WRA...L2X | ℃ | -20℃ to 70℃(-4°F to 158°F) | |||||
Viscosity range | mm2/s | 20 to 380(preferably 30 to 46) | ||||||
Degree of contamination | NAS1638 class9 or ISO 4406 class 20/18/15 | |||||||
Electrical data | ||||||||
1)solenoid | ||||||||
Voltage type | DC | |||||||
Command value signal | ±10V or 4~20mA | |||||||
Max. current per solenoid | A | 2.5 | 1.5 | 0.8 | ||||
Coil resistance | Cold value | Ω | 2 | 5 | 19.5 | |||
Max. warm value | 3 | 7.2 | 28.8 | |||||
Duty | % | ED100% | ||||||
Coil temperature | ℃ | 150 | ||||||
Valve protection to EN 60529 | IP 65 | |||||||
2)Control electronics | ||||||||
Ampilfier | 4WRA...L2X | VT-VSPA2-1-L1X | ||||||
4WRAE...L2X | Integrated in the valve(OBE) | |||||||
Operating voltage | Nominal voltage | VDC | 24 | |||||
Lower limiting value | V | 21/22(4WRA),19(4WRAE) | ||||||
Upper limiting value | V | 35 | ||||||
Amplifier current consumption | Imax | A | <1.8 | |||||
Imax | A | 3 |
ADD: Address: No. 81, Zhuhang Road, Minhang District, Shanghai(Shanghai Lixin Hydraulics Co., Ltd.)
TEL: 021-31616718 Tel: 021-31616718, ext. 8000 ( reception )
? 2023 Shanghai Lixin Hydraulics Co., Ltd. copyright hu13042344